Wodaplug mini / ABS PLC splitters

Wodaplug.com WDS mini package with steel tube optical Bare fibre PLC splitter 1 to 4-8-12 with connectors SC/PC

1. Product Introduction

PLC splitter is based on a quartz substrate integrated waveguide optical power distribution device, has the advantages of small volume, the working wavelength range, high reliability, good light uniformity etc characteristic, is especially suitable for passive optical network (EPON, BPON, GPON etc.) connected local and terminal equipment and realize the optical signal devide.

Bare PLC splitter is putting PLC splitter chip and input, output optical fiber array in a square metal tube, out with the diameter of 0.9mm or 250um bare fiber, fiber can be welded, can also be processing various types of optical fiber connector.

Wodaplug provides a whole series of 1xN and 2xN splitters that are tailored for specific applications. All products meet (YD/T1117-2001 All optical fiber branching device technical conditions), (YD-T 2000-209 PLC Integrated optical devices PLC optical power splitter) etc., and are certified by TLC for network deployment.

view on eshop

2. Specifications – Customisable Options :

1*2,1*4,1*8,1*12,1*32,1*64(with or without connectors)
2*2,2*4,2*8,2*16,2*32,2*64(with or without connectors)

– we can also deliver splitters with APC or LC connectors! Please contact us if you need spiecific solution.

3. Performance and Technical parameters

(test reports available for each splitter)

Technical dataSpecification(without connector loss)
Work wavelength (nm)1260-1650
Type1*41*81*161*322*42*82*162*32
Insertion loss(dB)≤7.3≤10.5≤13.5≤17.0≤7.6≤11.0≤14.5≤17.5
Uniformity(dB)≤0.6≤0.8≤1.2≤1.5≤0.8≤1.5≤1.5≤2.0
PDL(dB)≤0.3≤0.3≤0.3≤0.3≤0.2≤0.4≤0.4≤0.4
Return loss(dB)≧50directivity(dB)≧55
Work temperature (℃)-40-+85storage temperature (℃)-40-+85

4. Product size (mm)

Type1*21*41*81*161*32
L×W×H60×7×460×7×460×7×460×12×580×20×6
Type2*22*42*82*162*32
L×W×H

Check our casing section, casing on pictures is not part of product!

If you need any other type (2×2 2×4 1×16 1×32 etc etc) please contact us!

view on eshop

WDS PLC regular sized ABS splitters 1/2 – 1/64

Our splitters are equiped with default connector type: SC/PC !!!!

1X2 Single Mode PLC Splitter Test Report
S/N20140211001Operating wavelength(nm)1260~1650
Input Fiber Length(m)1,5Output Fiber Length(m)1,5
Operating Temperature(℃)-40~85Storage Temperature(℃)-40~85
Package Dimension(mm)100*80*10Fiber TypeG657A
Connector TypeSC/PCDate11.2.2014
Cable(mm)2,0QC: Approved
ChannelIL(dB)
1310nm1490nm1550nm
CH13,593,753,61
CH23,733,783,71
Uniformity(dB)@1310nm0,14PDL(dB)≤0.2
Uniformity(dB)@1490nm0,04Directivity(dB)≥55
Uniformity(dB)@1550nm0,10Return Loss(dB)≥55
1X4 Single Mode PLC Splitter Test Report
S/N20140228030Operating wavelength(nm)1260~1650
Input Fiber Length(m)1,5Output Fiber Length(m)1,5
Operating Temperature(℃)-40~85Storage Temperature(℃)-40~85
Package Dimension(mm)100*80*10Fiber TypeG657A
Connector TypeSC/PCDate28.2.2014
Cable(mm)2,0QC: Approved
ChannelIL(dB)
1310nm1490nm1550nm
CH16,766,686,81
CH26,726,636,75
CH36,856,776,79
CH46,686,896,69
Uniformity(dB)@1310nm0,17PDL(dB)≤0.2
Uniformity(dB)@1490nm0,26Directivity(dB)≥55
Uniformity(dB)@1550nm0,12Return Loss(dB)≥60
1X8 Single Mode PLC Splitter Test Report
S/N20140114001Operating wavelength(nm)1260~1650
Input Fiber Length(m)1,5Output Fiber Length(m)1,5
Operating Temperature(℃)-40~85Storage Temperature(℃)-40~85
Package Dimension(mm)100*80*10Fiber TypeG657A
Connector TypeSC/PCDate14.1.2014
Cable(mm)2,0QC: Approved
ChannelIL(dB)
1310nm1490nm1550nm
CH110,0810,139,94
CH210,2710,129,99
CH310,1510,1610,12
CH410,2010,0810,16
CH510,1010,0910,13
CH610,2510,1310,22
CH79,9510,0510,04
CH89,9010,0810,00
Uniformity(dB)@1310nm0,37PDL(dB)≤0.2
Uniformity(dB)@1490nm0,11Directivity(dB)≥55
Uniformity(dB)@1550nm0,28Return Loss(dB)≥60
1X16 Single Mode PLC Splitter Test Report
S/N20140211001Operating wavelength(nm)1260~1650
Input Fiber Length(m)1,5Output Fiber Length(m)1,5
Operating Temperature(℃)-40~85Storage Temperature(℃)-40~85
Package Dimension(mm)120*80*18Fiber TypeG657A
Connector TypeSC/PCDate
Cable(mm)2,0QC: Approved
ChannelIL(dB)
1310nm1490nm1550nm
CH113,3113,3513,17
CH212,9313,0413,15
CH313,3913,2213,37
CH413,2313,2513,03
CH512,9912,9313,40
CH612,9613,2113,08
CH713,2113,3613,01
CH813,3813,3813,48
CH912,9913,3712,93
CH1013,0213,4612,93
CH1113,0513,1513,07
CH1212,9813,1813,24
CH1313,0213,3012,92
CH1413,2213,4313,11
CH1513,4313,2113,27
CH1613,1413,0613,01
Uniformity(dB)@1310nm0,50PDL(dB)≤0.3
Uniformity(dB)@1490nm0,53Directivity(dB)≥55
Uniformity(dB)@1550nm0,56Return Loss(dB)≥60
1X32 Single Mode PLC Splitter Test Report
S/N:20140212301Operating wavelength(nm)1260~1650
Input Fiber Length(m)1,5Output Fiber Length(m)1,5
Operating Temperature(℃)-40~85Storage Temperature(℃)-40~85
Package Dimension(mm)120*80*18Fiber TypeG657A
Connector TypeSC/PCDate12.2.2014
Cable(mm)2,0QC: Approved
ChannelIL(dB)
1310nm1490nm1550nm
CH1
CH216,2716,4316,43
CH316,2716,4516,43
CH416,38
CH516,5116,4816,54
CH616,5116,2916,25
CH716,3216,4416,40
CH816,4116,4116,52
CH916,4616,2616,32
CH1016,3916,2916,43
CH1116,4916,3516,33
CH1216,3916,3616,32
CH1316,4116,4516,31
CH1416,3316,3316,52
CH1516,4516,2916,40
CH1616,2616,3916,51
CH1716,5516,3316,48
CH1816,4816,4516,51
CH1916,2516,2916,27
CH2016,5116,3116,26
CH2116,5216,4716,50
CH2216,3616,4616,27
CH2316,4116,4916,32
CH2416,3716,3416,34
CH2516,4516,3016,53
CH2616,2716,3216,39
CH2716,4016,2516,27
CH2816,5316,3516,39
CH2916,5116,2916,40
CH3016,5016,3116,42
CH3116,4516,3016,31
CH3216,3216,2716,44
Uniformity(dB)@1310nm0,29PDL(dB)≤0.3
Uniformity(dB)@1490nm0,26Directivity(dB)≥55
Uniformity(dB)@1550nm0,29Return Loss(dB)≥50
1X64 Single Mode PLC Splitter Test Report
S/N20140214011Operating wavelength(nm)1260~1650
Input Fiber Length(m)1,5Output Fiber Length(m)1,5
Operating Temperature(℃)-40~85Storage Temperature(℃)-40~85
Package Dimension(mm)140*115*18Fiber TypeG657A
Connector TypeSC/PCDate14.2.2014
Cable(mm)2,0QC: Approved
ChannelIL(dB)
1310nm1490nm1550nm
CH120,0219,6019,71
CH220,0019,6319,95
CH319,9219,4919,73
CH419,6919,8919,67
CH519,6619,6119,98
CH619,6719,9219,75
CH719,9719,7619,50
CH819,7419,4719,66
CH919,7219,6319,83
CH1019,5520,0019,74
CH1120,0419,6619,83
CH1219,8219,9319,97
CH1319,7619,8620,06
CH1419,9619,7219,75
CH1519,9219,8219,90
CH1619,4619,7019,81
CH1719,5119,8320,08
CH1819,6819,6119,65
CH1920,0019,8619,67
CH2019,8319,9019,58
CH2119,5919,6719,75
CH2219,9619,9219,52
CH2320,0120,0219,52
CH2420,0120,0119,59
CH2519,6219,8019,76
CH2619,5419,5919,80
CH2719,8819,6020,01
CH2819,7319,6720,02
CH2919,9920,0419,94
CH3019,6220,1019,82
CH3119,9719,7319,96
CH3219,9219,7919,46
CH3319,8820,0620,01
CH3419,8819,8719,95
CH3519,7219,7319,47
CH3620,0019,6119,70
CH3720,0419,8720,00
CH3819,6920,0719,60
CH3919,9119,5819,62
CH4019,7919,6419,51
CH4119,6119,6219,77
CH4220,0519,7419,57
CH4319,9519,5919,63
CH4419,6119,5920,08
CH4519,9520,0819,82
CH4620,0219,9519,72
CH4719,6119,6119,68
CH4819,9719,5320,09
CH4919,5319,7419,64
CH5019,9319,6219,99
CH5119,4819,4920,00
CH5219,5619,5019,75
CH5319,5319,8019,53
CH5420,0820,0519,48
CH5519,8919,5419,72
CH5619,4719,4619,76
CH5719,5719,7020,02
CH5819,8819,7319,74
CH5919,7419,8519,99
CH6019,5019,7920,02
CH6119,9219,5219,88
CH6219,9619,4719,68
CH6320,0319,6819,95
CH6419,6519,7719,86
Uniformity(dB)@1310nm0,61PDL(dB)≤0.3
Uniformity(dB)@1490nm0,64Directivity(dB)≥55
Uniformity(dB)@1550nm0,63Return Loss(dB)≥60